Compare Seaward PAT Testers

Use this table to compare all Seaward PAT testers and to find out which tester is right for you

We also have a comprehensive selection of printers, labels and other accessories available. Click here to view the compatibility table.

Seaward PAT Tester Comparison
General features Apollo 600
[View product]
Apollo 500
[View product]
Apollo 400
[View product]
Supernova Elite
[View product]
PrimeTest 250+
[View product]
PrimeTest 100
[View product]
PrimeTest 50
[View product]
On-board memory 50,000 records
+ 2,000 photos
10,000 records 2,000 records 6,000 records 999 records    
Handheld  
Battery/mains powered Mains or battery Mains or battery Mains or battery Mains Battery (requires
mains for PE
current test)
Battery Battery
Scanner & printer compatible
printer only
Printer only
(PATMobile app*)
Printer only
(PATMobile app*)
QWERTY keypad      
User configurable sequences 100 100 25 20      
User set sites and locations 100 100 50 19 sites
49 locations
     
Colour screen        
Auto-incrament asset ID        
Password controlled
user accounts
         
Multiple user accounts (with varying
privileges)
(with varying
privileges)
 
Clone tester facility          
User definable comment lines        
Configurable checklists for any
workplace test or inspection
         
Risk-based retest calculator          
Built in universal risk
assessment
           
On-board camera            
Health & safety certificates            
Earth resistance calculator      
Electrical test functions Apollo 600
[View product]
Apollo 500
[View product]
Apollo 400
[View product]
Supernova Elite
[View product]
PrimeTest 250+
[View product]
PrimeTest 100
[View product]
PrimeTest 50
[View product]
Accurate earth continuity circuit N/A
Mains supply check
IEC lead test
Earth test lead null 4-wire      
Earth continuity 200mA 200mA 200mA 100mA/200mA/
4A/10A/25A
200mA 200mA 200mA
Insulation resistance 250V/500V 250V/500V 250V/500V 250V/500V 250V/500V 500V 500V
PE conductor current (earth leakage) 230V only 230V only 230V only 230V/110V 230V only    
Touch current 230V only 230V only 230V only 230V/110V 230V only    
Alternative substitute leakage  
RCD test    
Flash test            
3 phase leakage Requires
adaptor
Requires
adaptor
Requires
adaptor
  Requires
adaptor
   
230V/110V input / output            
Point to point testing (requires accessories)        
Data transfer features Apollo 600
[View product]
Apollo 500
[View product]
Apollo 400
[View product]
Supernova Elite
[View product]
PrimeTest 250+
[View product]
PrimeTest 100
[View product]
PrimeTest 50
[View product]
Data transfer via USB flash drive            
USB download      
R3232 download            
Bluetooth        
PC download/upload Download only Download only    
Remote data transfer via mobile device Android & iOS Android only Android only     Manual entry
(PATMobile app)
Manual entry
(PATMobile app)