| Visual inspection entries via keyboard:- | |
| Protective Bonding | |
| Test Current | >10A into 0.33W (EN60204-1) |
| Measuring Range | 0.05V - 5V |
| Test Thresholds | 1.0V, 1.4V, 1.9V, 2.6V, 3.3V |
| Test Current | 25A into 0.1W |
| Measuring Range | 0.005W - 0.5W |
| Test Thresholds | 0.10W , 0.14W , 0.19W , 0.26W , 0.33W |
| Test Voltage | 6V O/C @ 50Hz |
| Accuracy | ±8% ±4 digits |
| Method | 4 wire (Kelvin) |
| Test Duration | 5, 10, 20, 60 seconds - selectable |
|
Insulation |
|
| Test Voltage | 500V DC @ 1mA |
| S/C Current | <10mA |
| Measuring Range |
0.1MW - 300MW |
| Pass/Fail | |
| Thresholds |
1.0MW |
| Accuracy |
±8% ±2 digit (0.1MW - 50MW) |
| Test Duration | 5, 10, 20, 60 seconds - selectable |
| Voltage Test | |
| EN60204 | |
| Test Voltage1 | >1000V O/C @ supply Volts |
| Test Current | >0.5A |
| Measuring | |
| Indication | Pass/Fail |
| Test Duration1 | 1, 2, 5, 10 seconds |
| EN60439 | |
| Test Voltage2 | >2500V O/C @ supply Hz |
| Test Current | >20mA max |
| Test Threshold | 5, 10, 15, 20, 500mA |
| Test Duration2 | 1, 2, 5, 10 seconds |
| 1 Available at power sockets or test probe | 2 Available at test probe only |
|
Residual Voltage |
|
| Input Range3 | 0V - 500V AC/DC |
| Measuring | |
| Indication | 30V - 370V |
| Test Threshold | 60V |
| Accuracy | ±8% |
| Test Duration | 1, 5 seconds - selectable |
| External Sense | |
| Voltage | 50V - 500V AC 50/60Hz |
|
Operations Test |
|
| Measuring Range4 | 0 - 4.0kVA |
| Accuracy | ±5% ±130kVA |
| Test Duration1 | 0.5, 1, 5, 15 minutes |
| General | |
| Supply Voltage | 220V - 240V (50/60 Hz) |
| Dimensions | 410 x 370 x 160mm |
| Weight | 10Kg |