ClareHAL 104
Advanced Multi-function Safety Tester
- The ultimate multi-function production line tester
- Internal memory
- Intuitive user interface
The ClareHAL 104 multi-function tester takes the features of the rest of the ClareHAL range and combines them into one easy unit. The simple intuitive user interface enables easy push-button manual testing, alternatively the full potential of this tester can be used to automate the testing sequence for fast performance on the most demanding production lines.
Tests can be started and stopped at the push of a button or choose from a variety of pre-selected automated configurations, including remote PCs, PLCs or interlocks. The internal memory stores up to 6000 test results and can be interfaced with various accessories. Tests: Earth bond, AC flash (hipot), DC flash (hipot), DC insulation resistance, ARC detection, Leakage, Load power, Power factor.
| ClareHAL Series Comparison | |||||
|---|---|---|---|---|---|
| Features | 100 | 101 | 102 | 103 | 104 |
| Earth/Ground Bond | |||||
| AC Flash/Hipot | |||||
| DC Flash/Hipot | |||||
| DC Insulation Resistance | |||||
| ARC Detection | |||||
| Leakage | |||||
| Load Power | |||||
| Power Factor | |||||
| Results Memory | |||||
| Automation Option | |||||
| Barcode scanner/printer Option | |||||
| Internal scanner | |||||
| Programmable Voltage Range | 0.10 kV-5.00 kV (10V/Step Resolution) |
| Frequency Independent of Supply | 50 or 60 Hz |
| Voltage Display Range and Accuracy | 0.10 kV-5.00kV ±1% ± 5 Counts |
| Voltage Display Resolution | 0.01kV |
| Current Display Range and Accuracy | 0.01mA-20.00mA ±1% ± 5 Counts |
| Current Display Resolution | 0.01mA |
| Selectable Range of Pass/Fail Levels | 0.01mA-20.00mA |
| Maximum Current Output | 20.00mA @5kV |
| Maximum Current Output Optional Arc Detection | 9 Levels |
| Programmable Voltage Range | 0.10 kV-6.00 kV (10V/Step Resolution) |
| Programmable Voltage Range Voltage Display Range and Accuracy | 0.10 kV-6.00kV ±1% ± 5 Counts |
| Voltage Display Resolution | 0.01kV |
| Current Display Range and Accuracy | 0.01mA-10.00mA ±1% ± 5 Counts |
| Current Display Resolution | 0.01mA |
| Selectable Range of Pass/Fail Levels | 0.01mA-10.00mA |
| Maximum Current Output | 10.00mA |
| Optional Arc Detection | 9 Levels |
| DC Output Voltage | 250V, 500, or 1000V Selectable |
| Display Range | 0.01MΩ-500MΩ |
| Display Range / Accuracy | 0.03MΩ - 350 MΩ ± 5% ± 5 Counts |
| 350MΩ -500 MΩ Indication Only | |
| Display Resolution | 0.01MΩ |
| Pass/Fail Level | 0.00MΩ-500.0MΩ |
| Test Voltage | Nominal 6V AC |
| Frequency | 50 or 60 Hz (independent of supply) |
| Display Range and Accuracy | 0-1500mΩ ±2% ±5 Counts |
| Display Resolution | 1 mΩ |
| Compliance Test Ranges | |
| Current/Load Resistance/Time | 5 A - 1000mΩ - Continuous |
| 10 A - 500mΩ - Continuous | |
| 25 A - 200 mΩ - Continuous | |
| 30 A - 150 mΩ - 60 secs | |
| 40A - 100 mΩ - 60 secs | |
| Settable Ouput Current Range | 0.1A - 40.0A |
| Selectable Range of Pass/Fail Levels | 0-1500 mΩ |
| Test Voltage | 110V - 230V AC 20A nominal (Vin-Vout) |
| Maximum Power Output | Up to 5.0kVA (dependant on mains supply rating) |
| Single Phase Power Measurement | |
| Display Range and Accuracy | 0.02kVA-5.00kVA ±2% ±0.02kVA |
| Selectable Range of Pass/Fail Levels | 0.001kVA-5.000kVA |
| Display Range and Accuracy Ratio | 0.000 -1.000 ± 0.030 |
| Selectable Range of Pass/Fail Levels | 0.000-1.000 |
| Display Range and Accuracy | 0.10mA-20.00 mA ± 1% ±5 Counts |
| Display Resolution | 0.01mA |
| Selectable Range of Pass/Fail Levels | 0.01mA-20mA |
| Display Range and Accuracy | 0.02mA - 5.00 mA ± 1% ±5 Counts |
| Display Resolution | 0.01 |
| Selectable Range of Pass/Fail Levels | 0.02mA-5.00mA |
| Measuring Device | IEC/EN 60990 Fig 4 |
| (IEC/EN 60990 Fig 3 or Fig 5 Upon Request) |