.jpg)
Test Currents: 10A AC
Display Range: 0.01ohms - 19.99ohms
Pass Value: User Defined
Measurement Technique: 4 wire measurement, floating earth
Earth Screen Continuity
Test Current: 200mA DC
Display Range: 0.01ohms - 19.99ohms
Pass Value: User Defined
Measurement Technique: 4 wire measurement, floating earth
Insulation Resistance
Test Voltage: 250V, 500V DC
Display Range: 0.1Mohms - 100Mohms
Pass Value: User Defined
Protective Conductor Current
Test Voltage: 230V
Display Range: 0.1mA - 09.99mA
Pass Value: User Defined
Touch Current
Test Voltage: 230V
Display Range: 0.1mA - 3.5mA
Pass Value: User Defined
Substitute Leakage
Tesr Voltage: 40V AC Nominal
Display Range: 0.20mA - 19.99mA
Pass Value: User Defined
Load Test
Display Range: 0kVA - 4.2kVA
IEC Lead Polarity
Tests Performed: Live/Neutral Continuity and Polarity
Operating Voltage
Voltage Range: 207V - 253V 45Hz - 65Hz
Weight / Dimensions
Weight and Dimensions: 3.5Kg / 31cm x 21cm x 8cm
Interfaces
Display Graphic: Large Format Custom LCD
Connectivity: 2 serial port connections